FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/24 Service Manual (AA-RTDXC-TE, July 2004)

Diagnostics
51Edge Switch 2/24 Service Manual
YES NO
The switch appears operational. Verify switch operation at the HAFM
appliance. Go to step 20.
48
Check FRUs for failure symptoms.
Are any amber LEDs associated with Fibre Channel ports illuminated?
NO YES
A Fibre Channel port failure is indicated. Go to step 38 to obtain
event codes. If no event codes are found, go to “MAP 0600: Port
Failure and Link Incident Analysis” on page 100. Exit MAP.
49
Is the amber ERR LED at the front of the switch illuminated?
NO YES
A FRU failure or link incident is indicated. Go to step 38 to obtain
event codes that identify the failure. Exit MAP.
50
Is the amber LED on a power supply illuminated?
NO YES
A power supply failure is indicated. Go to step 38 to obtain event
codes. If no event codes are found, go to “MAP 0100: Power
Distribution Analysis” on page 54. Exit MAP.
The switch appears operational. Exit MAP.
51
You are at the console of an open systems interconnection (OSI) server attached to
the switch reporting the problem. If an incident occurs on the Fibre Channel link
between the switch and server, a link incident record is generated and sent to the
server using the reporting procedure defined in T11/99-017v0.
Was a link incident record generated and sent to the switch-attached OSI server?
YES NO
Perform switch fault isolation at the HAFM appliance. Go to step 20.