FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/24 Service Manual (AA-RTDXC-TE, July 2004)

Diagnostics
49Edge Switch 2/24 Service Manual
40
Is the green PWR LED at the switch front bezel illuminated?
NO YES
Go to step 45.
41
Is the switch connected to facility AC power and powered on?
NO YES
Go to step 44.
42
Connect the switch to facility AC power. Inspect the switch for indications of
being powered on, such as:
At the front bezel, an illuminated PWR LED (green) or ERR LED (amber).
Illuminated LEDs adjacent to Fibre Channel ports.
Audio emanations and airflow from cooling fans.
Does the switch appear powered on?
YES NO
A power distribution problem is indicated. Go to step 38 to obtain
event codes. If no event codes are found, go to “MAP 0100: Power
Distribution Analysis” on page 54. Exit MAP.
43
Is the green PWR LED at the switch front bezel illuminated?
NO YES
Go to step 45.
A faulty PWR LED is indicated, but switch and Fibre Channel port operation is
not disrupted. The LED is connected to CTP card circuitry, and if this problem is a
concern to the customer, the switch must be replaced. Exit MAP.
44
Inspect the switch for indications of being powered on, such as:
At the front bezel, an illuminated PWR LED (green) or ERR LED (amber).