FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/24 Service Manual (AA-RTDXC-TE, July 2004)

Diagnostics
45Edge Switch 2/24 Service Manual
Go to step 35.
34
Beaconing is enabled for the FRU.
1. Consult the customer and next level of support to determine the reason FRU
beaconing is enabled.
2. Disable FRU beaconing.
a. At the Hardware View, right-click the FRU graphic. A pop-up menu
appears.
b. Click the Enable Beaconing option. The check mark disappears from the
box adjacent to the option, and FRU beaconing is disabled.
Was FRU beaconing enabled because FRU failure or degradation was suspected?
YES NO
The switch appears operational. Exit MAP.
Go to step 20 and perform fault isolation again (through the HAFM appliance).
35
Does a yellow triangle (attention indicator) overlay a port graphic?
YES NO
Go to step 37.
36
Inspect the port state and LED status for all ports with an attention indicator.
1. Double-click a port to open the Port Properties dialog box (Figure 11).