FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/24 Service Manual (AA-RTDXC-TE, July 2004)
Diagnostics
36 Edge Switch 2/24 Service Manual
12
Port beaconing is enabled.
1. Consult the customer and next level of support to determine the reason port
beaconing is enabled.
2. Disable port beaconing:
a. At the View panel, click Operations at the left side of the panel. The
Operations panel opens with the Beaconing page displayed.
b. Click the Beaconing State check box for the port. The check mark
disappears and port beaconing is disabled.
c. Return to the View panel (Port Properties tab).
Continue to the next step.
13
At the View panel, does the Operational State field display a Segmented
message?
NO YES
↓ Port segmentation is indicated. Go to step 18 to obtain event codes. If
no event codes are found, go to “MAP 0700: Fabric, ISL, and
Segmented Port Problem Determination” on page 118. Exit MAP.
14
At the View panel, does the Operational State field display a message indicating
a port problem?
NO YES
↓ Go to step 18 to obtain event codes. If no event codes are found, go to
“MAP 0600: Port Failure and Link Incident Analysis” on page 100.
Exit MAP.
15
Repeat step 11 through step 14 for each remaining Fibre Channel port for which a
problem is suspected (ports 0 through 23).
Is a problem indicated for any of the ports?
NO YES