FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/24 Service Manual (AA-RTDXC-TE, July 2004)

Event Codes
299Edge Switch 2/24 Service Manual
Table 108: Event Code 812
Message: CTP card shutdown due to thermal violation.
Severity: Major.
Explanation: A CTP failed and was powered off because of excessive heat. This event follows an
indication that the hot temperature threshold was reached or exceeded (event code
811).
Action: Replace the failed switch. Perform the data collection procedure and return the
backup disk and faulty switch to HP support personnel.
Event Data: No supplementary data included with this event.
Distribution: Switch HAFM Appliance Host
EWS
Event Log
System
Error LED
Event Log E-Mail Call
Home
Sense
Info
Link
Incident
✔✔✔✔✔✔
Table 109: Event Code 850
Message: System shutdown due to CTP card thermal violations.
Severity: Severe.
Explanation: The switch powered off because of excessive thermal violations on the CTP card.
Action: Replace the failed switch. Perform the data collection procedure and return the
backup disk and faulty switch to HP support personnel.
Event Data: No supplementary data included with this event.
Distribution: Switch HAFM Appliance Host
EWS
Event Log
System
Error LED
Event Log E-Mail Call
Home
Sense
Info
Link
Incident
✔✔✔✔✔✔