Event Codes
298 Edge Switch 2/24 Service Manual
Thermal Events (800 through 899)
Table 106: Event Code 810
Message: High temperature warning (CTP card thermal sensor).
Severity: Major.
Explanation: The thermal sensor associated with a CTP card indicates the warm temperature
threshold was reached or exceeded.
Action: Replace the failed switch. Perform the data collection procedure and return the
backup disk and faulty switch to Hewlett-Packard support personnel.
Event Data: No supplementary data included with this event.
Distribution: Switch HAFM Appliance Host
EWS
Event
Log
System
Error
Indicator
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔✔✔✔✔
Table 107: Event Code 811
Message: Critically hot temperature warning (CTP card thermal sensor).
Severity: Major.
Explanation: The thermal sensor associated with a CTP card indicates the hot temperature
threshold was reached or exceeded.
Action: Replace the failed switch. Perform the data collection procedure and return the
backup disk and faulty switch to Hewlett-Packard support personnel.
Event Data: No supplementary data included with this event.
Distribution: Switch HAFM Appliance Host