FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/24 Service Manual (AA-RTDXC-TE, July 2004)

Diagnostics
30 Edge Switch 2/24 Service Manual
510 SFP optical transceiver hot-insertion
initiated.
No action required.
512 SFP optical transceiver nonfatal error. Go to MAP 0600: Port
Failure and Link Incident
Analysis.
513 SFP optical transceiver hot-removal
completed.
No action required.
514 SFP optical transceiver failure. Go to MAP 0600: Port
Failure and Link Incident
Analysis.
523 FL_Port open request failed. No action required.
524 No AL_PA acquired. No action required.
525 FL_Port arbitration timeout. No action required.
581 Implicit incident. Go to MAP 0600: Port
Failure and Link Incident
Analysis.
582 Bit error threshold exceeded. Go to MAP 0600: Port
Failure and Link Incident
Analysis.
583 Loss of signal or loss of synchronization. Go to MAP 0600: Port
Failure and Link Incident
Analysis.
584 Not operational primitive sequence
received.
Go to MAP 0600: Port
Failure and Link Incident
Analysis.
585 Primitive sequence timeout. Go to MAP 0600: Port
Failure and Link Incident
Analysis.
586 Invalid primitive sequence received for
current link state.
Go to MAP 0600: Port
Failure and Link Incident
Analysis.
810 High temperature warning (CTP thermal
sensor).
Go to MAP 0500: FRU
Failure Analysis.
811 Critically hot temperature warning (CTP
thermal sensor).
Go to MAP 0500: FRU
Failure Analysis.
Table 4: Event Codes versus Maintenance Action (Continued)
Event