FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/24 Service Manual (AA-RTDXC-TE, July 2004)

Event Codes
297Edge Switch 2/24 Service Manual
Table 105: Event Code 586
Message: Invalid primitive sequence received for current link state.
Severity: Major.
Explanation: An attached OSI server recognized either a link reset (LR) or a link-reset response
(LRR) sequence while in the wait-for-online sequence (OLS) state.
Action: An LIR is generated and sent to the attached server using the reporting procedure
defined in T11/99-017v0 (OSI). If fault isolation at the server does not detect a
failure, the problem may be due to a port failure. Go to “MAP 0000: Start MAP
on page 32 to perform fault isolation.
Event Data: Refer to the T11/99-017v0 document for the specific link incident record format.
Distribution: Switch HAFM Appliance Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔