FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/24 Service Manual (AA-RTDXC-TE, July 2004)

Event Codes
295Edge Switch 2/24 Service Manual
Table 101: Event Code 582
Message: Bit error threshold exceeded.
Severity: Major.
Explanation: An attached OSI server determined the number of code violation errors recognized
exceeded the bit error threshold.
Action: An LIR is generated and sent to the attached server using the reporting procedure
defined in T11/99-017v0 (OSI). If fault isolation at the server does not detect a
failure, the problem may be due to a port failure. Go to “MAP 0000: Start MAP
on page 32 to perform fault isolation.
Event Data: Refer to the T11/99-017v0 document for the specific link incident record format.
Distribution: Switch HAFM Appliance Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔
Table 102: Event Code 583
Message: Loss of signal or loss of synchronization.
Severity: Major.
Explanation: An attached OSI server recognized a loss-of-signal condition or a
loss-of-synchronization condition that persisted for more than the specified
receiver-transmitter timeout value (R_T_TOV).
Action: An LIR is generated and sent to the attached server using the reporting procedure
defined in T11/99-017v0 (OSI). If fault isolation at the server does not detect a
failure, the problem may be due to a port failure. Go to “MAP 0000: Start MAP
on page 32 to perform fault isolation.
Event Data: Refer to the T11/99-017v0 document for the specific link incident record format.
Distribution: Switch HAFM Appliance Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔