FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/24 Service Manual (AA-RTDXC-TE, July 2004)
Event Codes
294 Edge Switch 2/24 Service Manual
Event Data: Byte 0 = port number (00 through 23).
Distribution: Switch HAFM Appliance Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔
Table 99: Event Code 525 (Continued)
Table 100: Event Code 581
Message: Implicit incident.
Severity: Major.
Explanation: An attached open systems interconnection (OSI) server recognized a condition
caused by an event that occurred at the server. The event caused an implicit Fibre
Channel link incident.
Action: A link incident record (LIR) is generated and sent to the attached server using the
reporting procedure defined in T11/99-017v0 (OSI). If fault isolation at the server
does not detect a failure, the problem may be due to a port failure. Go to “MAP
0000: Start MAP” on page 32 to perform fault isolation.
Event Data: Refer to the T11/99-017v0 document for the specific link incident record format.
Distribution: Switch HAFM Appliance Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔