FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/24 Service Manual (AA-RTDXC-TE, July 2004)
Event Codes
291Edge Switch 2/24 Service Manual
Distribution: Switch HAFM Appliance Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔
Table 92: Event Code 508 (Continued)
Table 93: Event Code 510
Message: SFP optical transceiver hot-insertion initiated.
Severity: Informational.
Explanation: Installation of a small form factor pluggable (SFP) optical transceiver was initiated
with the switch powered on and operational. The event indicates that operational
firmware detected the presence of the transceiver.
Action: No action required.
Event Data: Byte 0 = port number (00 through 23).
Bytes 4 through 7 = elapsed millisecond tick count.
Distribution: Switch HAFM Appliance Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔
Table 94: Event Code 512
Message: SFP optical transceiver nonfatal error.
Severity: Minor.
Explanation: Switch firmware detected an SFP optical transceiver non-fatal error.
Action: Replace the failed transceiver with a functional transceiver of the same type.
Event Data: Byte 0 = port number (00 through 23).
Byte 1 = engineering reason code.
Bytes 4 through 7 = elapsed millisecond tick count.
Distribution: Switch HAFM Appliance Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔