FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/24 Service Manual (AA-RTDXC-TE, July 2004)
Event Codes
290 Edge Switch 2/24 Service Manual
Table 91: Event Code 507
Message: Loopback diagnostics port failure.
Severity: Informational.
Explanation: A loopback diagnostic test detected a Fibre Channel port failure.
Action: No action required. An event code 506 is generated if this diagnostic failure results
in a hard port failure.
Event Data: Byte 0 = port number (00 through 23).
Byte 1 = engineering reason code.
Bytes 4 through 7 = elapsed millisecond tick count.
Bytes 8 through 11 = reason code specific.
Byte 12 = test type.
Distribution: Switch HAFM Appliance Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔
Table 92: Event Code 508
Message: Fibre Channel port anomaly detected.
Severity: Informational.
Explanation: The CTP detected a deviation in the normal operating mode or status of the
indicated Fibre Channel port.
Action: No action required. An event code 506 is generated if this anomaly results in a
hard port failure.
Event Data: Byte 0 = port number (00 through 23).
Byte 1 = anomaly reason code.
Bytes 4 through 7 = elapsed millisecond tick count.
Bytes 8 and 9 = high-availability error callout #1.
Bytes 10 and 11 = high-availability error callout #2.
Byte 12 = detecting port.
Byte 13 = connected port.