FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/24 Service Manual (AA-RTDXC-TE, July 2004)
Diagnostics
29Edge Switch 2/24 Service Manual
310 Cooling fan propeller recovered. No action required.
311 Cooling fan propeller recovered. No action required.
312 Cooling fan propeller recovered. No action required.
313 Cooling fan propeller recovered. No action required.
314 Cooling fan propeller recovered. No action required.
315 Cooling fan propeller recovered. No action required.
400 Power-up diagnostic failure. Go to MAP 0200: POST
Failure Analysis.
410 Switch reset. No action required.
411 Firmware fault. Go to MAP 0200: POST
Failure Analysis.
412 CTP watchdog timer reset. Go to “Collecting
Maintenance Data” on
page 165.
421 Firmware download complete. No action required.
423 CTP firmware download initiated. No action required.
426 Multiple ECC single-bit errors occurred. Go to MAP 0500: FRU
Failure Analysis.
433 Non-recoverable Ethernet fault. Go to MAP 0500: FRU
Failure Analysis.
440 Embedded port hardware failed. Go to MAP 0500: FRU
Failure Analysis.
442 Embedded port anomaly detected. No action required.
445 ASIC detected a system anomaly. No action required.
453 New feature key installed. No action required.
506 Fibre Channel port failure. Go to MAP 0600: Port
Failure and Link Incident
Analysis.
507 Loopback diagnostics port failure. Go to MAP 0600: Port
Failure and Link Incident
Analysis.
508 Fibre Channel port anomaly detected. No action required.
Table 4: Event Codes versus Maintenance Action (Continued)
Event
Code
Explanation Action