FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/24 Service Manual (AA-RTDXC-TE, July 2004)
Event Codes
286 Edge Switch 2/24 Service Manual
Table 85: Event Code 440
Message: Embedded port hardware failed.
Severity: Major.
Explanation: The embedded port hardware detected a fatal CTP error.
Action: Replace the switch.
Event Data: Byte 0 = CTP slot position (00).
Byte 1 = engineering reason code
Bytes 4 through 7 = elapsed millisecond tick count.
Distribution: Switch HAFM Appliance Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔✔✔✔✔
Table 86: Event Code 442
Message: Embedded port anomaly detected.
Severity: Informational.
Explanation: The switch detected a deviation in the normal operating mode or status of the
embedded port.
Action: No action required. An additional event code is generated if this incident exceeds
an error threshold or results in a port failure.
Event Data: Byte 0 = port number.
Byte 1 = engineering reason code.port.
Bytes 4 through 7 = elapsed millisecond tick count.
Bytes 8 and 9 = high-availability error callout #1.
Bytes 10 and 11 = high-availability error callout #2.
Byte 12 = detecting port.
Byte 13 = connected port.
Bytes 16 and 17 = high-availability error callout #3.
Bytes 18 and 19 = high-availability error callout #4.