FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/24 Service Manual (AA-RTDXC-TE, July 2004)

Event Codes
280 Edge Switch 2/24 Service Manual
CTP Card Events (400 through 499)
Table 74: Event Code 400
Message: Power-up diagnostics failure.
Severity: Major.
Explanation: Power-on self tests (POSTs) detected a faulty field-replaceable unit (FRU) as
indicated by the event data.
Action: If a CTP card failure is indicated, replace the switch. If a fan or power supply failure
is indicated, replace the power supply assembly. Perform the data collection
procedure and return the backup disk and faulty FRU to Hewlett-Packard support
personnel.
Event Data: Byte 0 = FRU code as follows: 02 = CTP card, 05 = cooling fan, 06 = power supply
assembly.
Byte 1 = FRU slot number.
Distribution: Switch HAFM Appliance Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔✔✔✔✔
Table 75: Event Code 410
Message: Switch reset.
Severity: Informational.
Explanation: The switch reset due to system power-up, IML, or manual reset. A software reset can
occur automatically after a firmware fault (event code 411), or be user-initiated.
Event data indicates the type of reset.
Action: No action required.
Event Data: Byte 0 = reset type as follows: 00 = power-on, 02 = IML, 04 = reset.
Distribution: Switch HAFM Appliance Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔