FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/24 Service Manual (AA-RTDXC-TE, July 2004)
Diagnostics
28 Edge Switch 2/24 Service Manual
140 Congestion detected on an ISL. Go to MAP 0700: Fabric,
ISL, and Segmented Port
Problem Determination.
141 Congestion relieved on an ISL. No action required.
142 Low BB_Credit detected on an ISL. Go to MAP 0700: Fabric,
ISL, and Segmented Port
Problem Determination.
143 Low BB_Credit relieved on an ISL. No action required.
150 Zone merge failure. Go to MAP 0700: Fabric,
ISL, and Segmented Port
Problem Determination.
151 Fabric configuration failure. Go to “Collecting
Maintenance Data” on
page 165.
200 Power supply AC voltage failure. Go to MAP 0100: Power
Distribution Analysis.
201 Power supply DC voltage failure. Go to MAP 0100: Power
Distribution Analysis.
203 Power supply AC voltage recovery. No action required.
204 Power supply DC voltage recovery. No action required.
206 Power supply removed. Replace FRU.
207 Power supply installed. No action required.
300 Cooling fan propeller failed. Go to MAP 0500: FRU
Failure Analysis.
301 Cooling fan propeller failed. Go to MAP 0500: FRU
Failure Analysis.
302 Cooling fan propeller failed. Go to MAP 0500: FRU
Failure Analysis.
303 Cooling fan propeller failed. Go to MAP 0500: FRU
Failure Analysis.
304 Cooling fan propeller failed. Go to MAP 0500: FRU
Failure Analysis.
305 Cooling fan propeller failed. Go to MAP 0500: FRU
Failure Analysis.
Table 4: Event Codes versus Maintenance Action (Continued)
Event
Code
Explanation Action