FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/24 Service Manual (AA-RTDXC-TE, July 2004)

Event Codes
277Edge Switch 2/24 Service Manual
Table 68: Event Code 310
Message: Cooling fan propeller recovered.
Severity: Informational.
Explanation: One cooling fan (out of six) recovered or the associated power supply assembly was
replaced. All fans are operational.
Action: No action required.
Event Data: The first byte of event data (byte 0) specifies the recovered fan number.
Distribution: Switch HAFM Appliance Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔
Table 69: Event Code 311
Message: Cooling fan propeller recovered.
Severity: Informational.
Explanation: Two cooling fans (out of six) recovered or the associated power supply assembly (or
assemblies) were replaced. All fans are operational.
Action: No action required.
Event Data: The first byte of event data (byte 0) specifies the recovered fan numbers.