FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/24 Service Manual (AA-RTDXC-TE, July 2004)

Event Codes
276 Edge Switch 2/24 Service Manual
Table 66: Event Code 304
Message: Cooling fan propeller failed.
Severity: Major.
Explanation: Five cooling fans (out of six) failed or are rotating at insufficient angular velocity.
The remaining fan is operational. The amber LED illuminates at the rear of both
power supply assemblies the fans.
Action: Replace both power supply assemblies.
Event Data: The first byte of event data (byte 0) specifies the failed fan numbers.
Distribution: Switch HAFM Appliance Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔✔✔✔✔
Table 67: Event Code 305
Message: Cooling fan propeller failed.
Severity: Major.
Explanation: All six cooling fans failed or are rotating at insufficient angular velocity. The amber
LED illuminates at the rear of both power supply assemblies.
Action: Replace both power supply assemblies.
Event Data: The first byte of event data (byte 0) specifies the failed fan numbers.
Distribution: Switch HAFM Appliance Host