FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/24 Service Manual (AA-RTDXC-TE, July 2004)

Event Codes
272 Edge Switch 2/24 Service Manual
Table 59: Event Code 206
Message: Power supply removed.
Severity: Informational.
Explanation: A power supply was removed while the Switch was powered on and operational.
The second power supply assumes the full operating load for the switch.
Action: No action required or install an operational power supply.
Event Data: No supplementary data included with this event.
Distribution: Switch HAFM Appliance Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔
Table 60: Event Code 207
Message: Power supply installed.
Severity: Informational.
Explanation: A redundant power supply was installed with the switch powered on and
operational. Both power supplies adjust to share operating load for the switch.
Action: No action required.
Event Data: No supplementary data included with the event.
Distribution: Switch HAFM Appliance Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔
Table 61: Event Code 208
Message: Power supply false shutdown.
Severity: Major.
Explanation: Switch operational firmware nearly shut down the indicated power supply as a result
of failure or facility power loss or voltage fluctuation.
Action: Confirm operation of facility power. If subsequent power loss events occur, replace
the failed power supply. Perform the data collection procedure and return the
backup disk and failed power supply to HP support personnel.