Power Supply Events (200 through 299)
Table 54: Event Code 200
Message: Power supply AC voltage failure.
Severity: Major.
Explanation: Alternating current (AC) input to the indicated power supply is disconnected or AC
circuitry in the power supply failed. The second power supply assumes the full
operating load for the switch.
Action: Ensure the power supply is connected to facility AC power, and verify operation of
the facility power source. If the AC voltage does not recover (indicated by event
code 203), replace the failed power supply. Perform the data collection procedure
and return the backup disk and failed power supply to Hewlett-Packard support
personnel.
Event Data: No supplementary data included with this event.
Distribution: Switch HAFM Appliance Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔✔✔✔✔
Table 55: Event Code 201
Message: Power supply DC voltage failure.
Severity: Major.
Explanation: Direct current (DC) circuitry in the power supply failed. The second power supply
assumes the full operating load for the switch.
Action: Replace the failed power supply. Perform the data collection procedure and return
the backup disk and failed power supply to Hewlett-Packard support personnel.
Event Data: No supplementary data included with this event.