FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/24 Service Manual (AA-RTDXC-TE, July 2004)
Event Codes
258 Edge Switch 2/24 Service Manual
Event Code: 071 (continued)
Event Data
(continued):
4 = Build fabric protocol error. A protocol error was detected during incorporation
of the switch into the fabric. Disconnect the E_Port link, reconnect the link, and IPL
the switch. If the condition persists, perform the data collection procedure and
return the backup disk to Hewlett-Packard support personnel.
5 = No principal switch. No Director or Edge Switch in the fabric can become the
principal switch. Modify the switch priority to any value other than 255.
6 = No response from attached switch (hello timeout). The switch periodically
verifies operation of attached fabric elements (Director or Edge Switch). The switch
E_Port (at the operational switch) times out and segments if the attached device
does not respond. Check the status of the attached Director or Edge Switch. If the
condition persists, perform the data collection procedure (at the attached device)
and return the backup disk to Hewlett-Packard support personnel.
Distribution: Switch HAFM Appliance Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔
Table 40: Event Code 071 (Continued)
Table 41: Event Code 072
Message: E_Port connected to unsupported switch.
Severity: Informational.
Explanation: The switch is attached (through an ISL) to an incompatible fabric element (Director
or Edge Switch).
Action: Disconnect the ISL.
Event Data: No supplementary data included with this event.
Distribution: Switch HAFM Appliance Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔