FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/24 Service Manual (AA-RTDXC-TE, July 2004)

Event Codes
257Edge Switch 2/24 Service Manual
Event Code: 070 (continued)
Distribution: Switch HAFM Appliance Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔
Table 39: Event Code 070 (Continued)
Table 40: Event Code 071
Message: Switch is isolated.
Severity: Informational.
Explanation: The switch is isolated from other fabric elements (Director or Edge Switch). This
event code is accompanied by one or more 070 event codes. Refer to the event
data for the segmentation reason.
Action: Action depends on the segmentation reason specified in the event data.
Event Data: The first byte of event data (byte 0) specifies the E_Port number. The fifth byte (byte
4) specifies the segmentation reason as follows:
1 = Incompatible operating parameters. Ether the resource allocation time out
value (R_A_TOV) or error detect time out value (E_D_TOV) is inconsistent between
the switch and another fabric element (Director or Edge Switch). Modify the
R_A_TOV and E_D_TOV to make the values consistent for all fabric Directors and
Edge Switches.
2 = Duplicate domain ID. The switch has the same preferred domain ID as another
fabric element (Director or Edge Switch). Modify the switch’s Domain ID to make it
unique.
3 = Incompatible zoning configurations. The same name is applied to a zone for
the switch and another fabric element (Director or Edge Switch), but the zones
contain different zone members. Modify the zone name to make it unique, or
ensure zones with the same name contain identical zone members.