FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/24 Service Manual (AA-RTDXC-TE, July 2004)
Event Codes
254 Edge Switch 2/24 Service Manual
Table 36: Event Code 061
Message: Fabric Controller database invalid.
Severity: Minor.
Explanation: Following an IML, or firmware download, the Fabric Controller database failed its
CRC validation. All Fabric Controller databases are initialized to an empty state,
resulting in a momentary loss of interswitch communication capability.
Action: Perform the data collection procedure and return the backup disk to
Hewlett-Packard support personnel.
Event Data: No supplementary data included with this event.
Distribution: Switch HAFM Appliance Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔✔✔✔
Table 37: Event Code 062
Message: Maximum interswitch hop count exceeded.
Severity: Informational.
Explanation: The fabric controller software detected that a path to another fabric element
(Director or Edge Switch) traverses more than seven interswitch links (ISLs or hops).
This may result in Fibre Channel frames persisting in the fabric longer than
standard timeout values allow.
Action: If possible, reconfigure the fabric so the path between any two Directors or Edge
Switches traverses no more than seven ISLs.
Event Data: Byte 0 = domain ID of the fabric element (Director or Edge Switch) more than seven
hops away.
Distribution: Switch HAFM Appliance Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔