FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/24 Service Manual (AA-RTDXC-TE, July 2004)
Messages
240 Edge Switch 2/24 Service Manual
Invalid value for
R_A_TOV.
Value for R_A_TOV
must be an integer from
10 through 1200.
Measured in tenths of a
second.
Enter a value from 10 to
1200.
Invalid value for second
(0–59).
Value for second must
be an integer from 0
through 59.
Enter a value from 0
through 59.
Invalid value for
threshold (1-99)%.
Value entered for each
port in the Configure
Open Trunking dialog
box must be in the range
from 1 to 99. This
message only displays if
the optional Open
Trunking feature is
installed.
Enter a number from 1 to
99 into the Threshold %
column of the Configure
Open Trunking dialog box.
Invalid value for year. Value for year must be a
four-digit year after
1980.
Enter a correct four-digit
value for the year.
Invalid World Wide
Name.
World Wide Name must
have eight two-digit
hexadecimal numbers
separated by colons
(xx:xx:xx:xx:xx:xx:xx:xx
)
Enter a World Wide Name
using eight two-digit
hexadecimal numbers
separated by colons in the
format given in the
message.
Link dropped. Connection between
HAFM appliance and
the switch has been lost.
Wait for the connection to
re-establish. Link
re-connects are attempted
every 30 seconds.
Log is currently in use. Log is in use by another
Element Manager.
Retry the operation later.
Loopback plug(s) must
be installed on ports
being diagnosed. Press
Next to continue.
External loopback
diagnostics require an
optical loopback plug to
be installed.
Ensure that an optical
loopback plug is installed
in port optical transceiver
before running external
wrap diagnostic testing.
Maximum number of
versions already
installed.
The maximum number of
firmware versions has
been reached.
Delete a firmware version
before adding a new
firmware version.
Table 30:
Edge Switch 2/24 Element Manager Messages (Continued)
Message Description Action