FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/24 Service Manual (AA-RTDXC-TE, July 2004)

Messages
226 Edge Switch 2/24 Service Manual
The maximum number
of zones per zone set
has already been
configured.
The maximum number of
zones that can be
defined in a zone set was
reached.
Delete an existing zone
before adding a new zone
to the zone set.
The nickname does not
exist.
The entered nickname
does not exist in the
fabric.
Configure the nickname to
the appropriate product or
select an existing
nickname.
The nickname is already
assigned. Either use a
different name or do not
save the name as a
nickname.
The entered nickname
already exists in the
fabric. Each nickname
must be unique.
Define a different
nickname.
The software version on
this HAFM appliance is
not compatible with the
version on the remote
HAFM appliance.
A remote HAFM
appliance connecting to
the HAFM appliance must
be running the same
software version to log in.
Upgrade the software
version on the downlevel
HAFM appliance.
The zoning library
conversion must be
completed before
continuing.
The zoning library
conversion is incomplete
and the requested
operation cannot
continue.
Complete the zoning
library conversion, then
retry the operation.
This fabric log is no
longer valid because the
fabric has been
unpersisted.
The selected Fabric Log is
no longer available
because the fabric was
unpersisted.
To start a new log for the
fabric, persist the fabric
through the Persist Fabric
dialog box.
This network address
has already been
assigned.
The specified IP address
was assigned and
configured. A unique
address must be
assigned.
Consult with the customer’s
network administrator to
determine a new IP
address to be assigned and
configured.
This product is not
managed by this HAFM
appliance.
The product selected is
not managed by this
HAFM appliance.
Select a product managed
by this HAFM appliance or
go to the HAFM appliance
that manages the affected
product.
Table 29: HAFM application messages (Continued)
Message Description Action