FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/24 Service Manual (AA-RTDXC-TE, July 2004)
Messages
220 Edge Switch 2/24 Service Manual
Invalid network address. The IP address specified
for the product is
unknown to the domain
name server (invalid).
Verify and enter a valid
product IP address.
Invalid port number.
Valid ports are (0-< nn
>).
The user has specified an
invalid port number.
Specify a valid port
number, in the range 0 to
the maximum number of
ports on the product minus
one. For example, for a
switch with 24 ports, the
valid port range is 0 to 23.
Invalid product
selection.
At the New Product
dialog box, an invalid
product was selected.
Select a valid product and
retry the operation.
Invalid request. Three conditions result in
this message:
■ The user tried to add
or modify a product
from Product View
and the network (IP)
address is already in
use. Network
addresses must be
unique.
■ The user tried to
create a new user
with a user name
that already exists.
User names must be
unique.
■ The user tried to
delete default
Administrator user.
The default
Administrator user
cannot be deleted.
Select the action that is
appropriate to the activity
that caused the error:
■ Network address:
Specify a unique
network (IP) address
for the product.
■ User name: Specify a
unique user name for
the new user ID.
■ Do not delete the
default Administrator
user.
Invalid UDP port
number.
The specified user
datagram protocol (UDP)
port number is invalid.
The number must be an
integer from 1 through
65535 inclusive.
Verify and enter a valid
UDP port number.
Table 29: HAFM application messages (Continued)
Message Description Action