FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/24 Service Manual (AA-RTDXC-TE, July 2004)

FRU Removal and Replacement
199Edge Switch 2/24 Service Manual
Figure 56: Redundant power supply removal and replacement
4. Perform one of the following to inspect the Event Log. Note that multiple
events appear because the power supply contains three internal cooling fans.
If at a Web browser connected to the EWS interface, click the Log tab at the
Monitor panel. The Event Log displays. The following event codes appear:
200–Power supply AC voltage failure (recorded when AC power is
disconnected).
300–A cooling fan propeller has failed (first fan).
301–A cooling fan propeller has failed (second fan).
302–A cooling fan propeller has failed (third fan).
206–Power supply removed.
If at the HAFM appliance, open the Hardware View, click Logs > Event
Log. The Event Log displays. The Event Log displays. The following event
codes appear:
200–Power supply AC voltage failure (recorded when AC power is
disconnected).
300–A cooling fan propeller has failed (first fan).
301–A cooling fan propeller has failed (second fan).
302–A cooling fan propeller has failed (third fan).
206–Power supply removed.