FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/24 Service Manual (AA-RTDXC-TE, July 2004)
Repair Information
184 Edge Switch 2/24 Service Manual
Reset Configuration Data
Note: This procedure resets the switch IP address to the default of 10.1.1.10 and may
disrupt server-to-switch communication. All optional features are disabled.
To reset the switch data to the factory default settings:
1. Notify the customer the switch is to be set offline. Ensure the customer’s
system administrator quiesces Fibre Channel frame traffic through the switch
and sets attached devices offline.
2. Set the switch offline (“Set Offline State” on page 175).
3. Open the HAFM application. The View All - HAFM 8 main window displays.
4. Double-click the icon representing the switch for which the configuration file
will be reset to factory default settings. The Hardware View for the selected
switch displays.
5. Choose Maintenance > Reset Configuration. The Reset Configuration
dialog box displays.
6. Click Reset. When the reset process finishes, the dialog box closes and the
application returns to the Hardware View.
7. The switch IP address resets to the default address of 10.1.1.10.
— If the configured IP address (prior to reset) was the same as the default
address, the switch-to-HAFM appliance Ethernet link is not affected and
the procedure is complete.
— If the configured IP address (prior to reset) was not the same as the default
address, the switch-to-HAFM appliance Ethernet link drops and HAFM
appliance communication is lost. Continue to the next step.
8. To change the switch IP address and restart the HAFM appliance session, go
to step 10.
9. To restart an HAFM appliance session using the default IP address of
10.1.1.10:
a. Close the Edge Switch 2/24 Element Manager application and return to
HAFM application.
b. A gray square with a yellow exclamation mark displays adjacent to the
icon representing the reset switch, indicating the switch is not
communicating with the HAFM appliance.