FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/24 Service Manual (AA-RTDXC-TE, July 2004)
Repair Information
168 Edge Switch 2/24 Service Manual
IML, IPL, or Reset the Switch
This section describes procedures to IML, IPL, or reset the Edge Switch. An IML
or reset is performed at the switch front panel using the IML/RESET button. An
IPL is performed from the HAFM appliance (Element Manager application). The
EWS interface does not provide an IML, IPL, or switch reset function.
Caution: A reset should only be performed if a CTP card failure is indicated.
Do not reset the switch unless directed to do so by a procedural step or the
next level of support.
An IML and IPL are functionally equivalent. The operations do not cause
power-on diagnostics to execute and are not disruptive to Fibre Channel traffic.
Both the IML and IPL operations:
■ Reload switch firmware from FLASH memory.
■ Reset the Ethernet LAN interface, causing the connection to the HAFM
appliance to drop momentarily until the connection automatically recovers.
A switch reset is more disruptive and resets the:
■ Microprocessor and functional logic for the CTP card. It also reloads the
firmware from FLASH memory.
■ Ethernet LAN interface, causing the connection to the HAFM appliance to
drop momentarily until the connection automatically recovers.
■ Ports, causing all Fibre Channel connections to drop momentarily until the
connections automatically recover. This causes attached devices to log out and
log back in. After the login, data frames lost during switch reset must be
retransmitted.