FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/24 Service Manual (AA-RTDXC-TE, July 2004)

Repair Information
163Edge Switch 2/24 Service Manual
Collecting Maintenance Data
When the switch operational firmware detects a critical error or FRU failure, the
switch automatically copies the contents of dynamic random access memory
(DRAM) to a dump area in FLASH memory on the active CTP card, then initiates
a failover to the operational FRU. The switch then transfers (through the Ethernet
connection) the captured dump file from FLASH memory to the HAFM appliance
hard drive.
Note: An optional full-volatility feature is often required at military sites that process
classified data. If the feature is enabled through a product feature enablement (PFE)
key, a memory dump file (that possibly includes classified Fibre Channel frames) is not
included as part of the data collection procedure.
Perform the maintenance data collection procedure after a firmware fault is
corrected or a failed FRU is replaced to capture the data for analysis by third-level
support personnel. Maintenance data includes the dump file, Hardware Log, Audit
Log, and an engineering log viewable only by support personnel. To collect
maintenance data:
1. Open the HAFM application. The View All - HAFM 8 main window displays.
2. Double-click the icon representing the switch for which the data collection
procedure will be performed. The Hardware View for the selected switch
displays.
3. Choose Maintenance > Data Collection. The Save Data Collection dialog
box displays, as shown in Figure 42.
Figure 42: Save Data Collection dialog box