FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/24 Service Manual (AA-RTDXC-TE, July 2004)
Repair Information
151Edge Switch 2/24 Service Manual
■ #—The switch port number (0 through 139 inclusive).
■ Name—The port name configured through the Configure Ports dialog box.
■ Block Config—The port status (Blocked or Unblocked).
■ State—The operating state of the port. Valid states are:
— Online, Offline, or Testing
— Beaconing
— Invalid Attachment
— Link Incident or Link Reset
— No Light, Not Operational, or Port Failure
— Segmented E_Port
■ Type—The type of port. Valid port types are a generic port (G_Port) not
connected to a Fibre Channel device, director, or switch (therefore light is not
transmitted); a fabric port (F_Port) connected to a device; or an expansion
port (E_Port) connected to a director or switch to form an interswitch link
(ISL).
■ Operating Speed—The operating speed of the port (Not Established, 1, or 2
Gb/sec.).
■ Alert—If Link Incident (LIN) alerts are configured for the port through the
Configure Ports dialog box, a yellow triangle displays in the column when a
link incident occurs. A yellow triangle also displays if beaconing is enabled
for the port. A red and yellow diamond displays if the port fails.
Double-click anywhere in a row for an installed port to open the Port Properties
dialog box.
Right-click anywhere in a row for an installed port to open a menu to:
■ Open the Port Properties, Node Properties, or Port Technology dialog boxes.
■ Block or unblock the port.
■ Enable or disable port beaconing.
■ Perform port diagnostics.
■ Clear link incident alerts.
■ Reset the port.
■ Configure port binding.
■ Clear threshold alerts.