18
A switch E_Port segmented because a build fabric protocol error was detected.
1. Disconnect the fiber-optic jumper cable from the segmented E_Port.
2. Reconnect the cable to the same port.
Did disconnecting and reconnecting the cable solve the problem and did both
switches join through the ISL to form a fabric?
NO YES
The switch, associated ISL, and multiswitch fabric appear
operational. Exit MAP.
19
Initial program load (IPL) the switch. Refer to “IML, IPL or Reset the Switch” on
page 171.
Did the IPL solve the problem and did both switches join through the ISL to form
a fabric?
NO YES
The switch, associated ISL, and multiswitch fabric appear
operational. Exit MAP.
Perform the data collection procedure and contact the next level of support. Exit
MAP.
20
A switch E_Port segmented because no switch in the fabric is capable of
becoming the principal switch.
1. Notify the customer the switch will be set offline. Ensure the system
administrator quiesces Fibre Channel frame traffic through the switch and sets
attached devices offline.
2. Set the switch offline. Refer to “Set the Switch Online or Offline” on
page 174.
3. At the Hardware View for the switch reporting the problem, click
Configure >Operating Parameters > Fabric Parameters. The Configure
Fabric Parameters dialog box displays.