Diagnostics
118 Edge Switch 2/24 Service Manual
4. At the Hardware View for the first switch reporting the problem, click
Configure > Operating Parameters > Switch Parameters. The Configure
Switch Parameters dialog box displays (Figure 31).
Figure 31: Configure Switch Parameters dialog box
5. Type the customer-determined preferred domain ID value, then click
Activate.
6. Repeat steps d and e at the Hardware View for the switch attached to the
segmented E_Port (second switch). Use a different preferred domain ID value.
7. Set both switches online. Refer to “Set the Switch Online or Offline” on
page 174.
Did the domain ID change solve the problem and did both switches join through
the ISL to form a fabric?
NO YES
The switch, associated ISL, and multiswitch fabric appear
operational. Exit MAP.
Contact the next level of support. Exit MAP.
17
A switch E_Port segmented because two switches had incompatible zoning
configurations. An identical zone name is recognized in the active zone set for
both switches, but the zones contain different members.
1. Work with the system administrator to determine the desired zone name
change for one of the affected switches. Zone names must conform to the
following rules:
The name must be 64 characters or fewer in length.