FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/24 Service Manual (AA-RTDXC-TE, July 2004)
Diagnostics
117Edge Switch 2/24 Service Manual
Figure 30: Configure Fabric Parameters dialog box
5. Type the recommended E_D_TOV and R_A_TOV values, then click
Activate.
6. Repeat steps d and e at the Hardware View for the switch attached to the
segmented E_Port (second switch). Use the same E_D_TOV and R_A_TOV
values.
7. Set both switches online. Refer to “Set the Switch Online or Offline” on
page 174.
Did the operating parameter change solve the problem and did both switches join
through the ISL to form a fabric?
NO YES
↓ The switch, associated ISL, and multiswitch fabric appear
operational. Exit MAP.
Contact the next level of support. Exit MAP.
16
A switch E_Port segmented because two fabric elements had duplicate domain
IDs.
1. Work with the system administrator to determine the desired domain ID
(1 through 23 inclusive) for each switch.
2. Notify the customer both switches will be set offline. Ensure the system
administrator quiesces Fibre Channel frame traffic through the switches and
sets attached devices offline.
3. Set both switches offline. Refer to “Set the Switch Online or Offline” on
page 174.