FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/24 Service Manual (AA-RTDXC-TE, July 2004)
Diagnostics
116 Edge Switch 2/24 Service Manual
A 071 event code indicates the switch is isolated from all switches in a
multiswitch fabric, and is accompanied by a 070 event code for each segmented
E_Port. The 071 event code is resolved when all 070 events are corrected.
Obtain supplementary event data for each 070 event code.
1. At the Hardware View, click Logs > Event Log. The Event Log displays.
2. Examine the first five bytes (0 through 4) of event data.
3. Byte 0 specifies the switch port number (00 through 23) of the segmented
E_port. Byte 4 specifies the segmentation reason as specified in Table 19.
15
A switch E_Port segmented because the error detect time out value (E_D_TOV)
or resource allocation time out value (R_A_TOV) is incompatible with the
attached fabric element.
1. Contact HP support to determine the recommended E_D_TOV and
R_A_TOV values for both switches.
2. Notify the customer both switches will be set offline. Ensure the system
administrator quiesces Fibre Channel frame traffic through the switches and
sets attached devices offline.
3. Set both switches offline. Refer to “Set the Switch Online or Offline” on
page 174.
4. At the Hardware View for the first switch reporting the problem, click
Configure > Operating Parameters > Fabric Parameters. The Configure
Fabric Parameters dialog box displays (Figure 30).
Table 17: Byte 4 Segmentation Reasons and Actions
Byte 4 Segmentation Reason Action
01 Incompatible operating parameters. Go to step 15.
02 Duplicate domain ID. Go to step 16.
03 Incompatible zoning configurations. Go to step 17.
04 Build fabric protocol error. Go to step 18.
05 No principal switch. Go to step 20.
06 No response from attached switch (hello timeout). Go to step 21.