FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/24 Service Manual (AA-RTDXC-TE, July 2004)
Diagnostics
114 Edge Switch 2/24 Service Manual
9
A minor error occurred that caused the Fabric Services database to be
re-initialized to an empty state. As a result, a disruptive fabric logout and login
occurred for all attached devices. The following list explains the error:
■ Event code 011–The Login Server database failed cyclic redundancy check
(CRC) validation.
■ Event code 021–The Name Server database failed CRC validation.
All attached devices resume operation after fabric login. Perform the data
collection procedure and return the CD to HP for analysis. Exit MAP.
10
A minor error occurred that caused the HAFM appliance database to be
re-initialized to an empty state. As a result, a disruptive server logout and login
occurred for all attached devices. The following list explains the error:
■ Event code 051–The HAFM appliance database failed CRC validation.
■ Event code 052–An internal operating error was detected by the HAFM
appliance subsystem.
All attached devices resume operation after HAFM appliance login. Perform the
data collection procedure and return the CD to HP for analysis. Exit MAP.
11
As indicated by an event code 061, a minor error occurred that caused the Fabric
Controller database to be re-initialized to an empty state and fail CRC validation.
As a result, the switch briefly lost interswitch link capability.
Table 16: Port Segmentation Reasons and Actions (HAFM Appliance)
Segmentation Reason Action
Incompatible operating parameters. Go to step 15.
Duplicate domain ID. Go to step 16.
Incompatible zoning configurations. Go to step 17.
Build fabric protocol error. Go to step 18.
No principal switch. Go to step 20.
No response from attached switch (hello timeout). Go to step 21.