FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/24 Service Manual (AA-RTDXC-TE, July 2004)

Diagnostics
113Edge Switch 2/24 Service Manual
6
At the HAFM appliance, does a yellow triangle (attention indicator) appear
adjacent to a Fibre Channel port graphic at the Hardware View?
YES NO
The problem is transient and the switch-to-fabric element connection
appears operational. Exit MAP.
7
Inspect the port state and LED status for all ports with an attention indicator.
1. At the Hardware View, double-click the port graphic with the attention
indicator. The Port Properties dialog box displays.
2. Inspect the Operational State field at the Port Properties dialog box.
Does the Operational State field indicate Segmented E_Port?
YES NO
Analysis for other port or link incident problems is not described in
this MAP. Go to “MAP 0600: Port Failure and Link Incident
Analysis” on page 100. Exit MAP.
8
Inspect the Reason field at the Port Properties dialog box. Table 18 lists port
segmentation reasons and associated steps that describe fault isolation procedures.
Table 15: Port Segmentation Reasons and Actions (EWS)
Segmentation Reason Action
Incompatible operating parameters. Go to step 15.
Duplicate domain ID. Go to step 16.
Incompatible zoning configurations. Go to step 17.
Build fabric protocol error. Go to step 18.
No principal switch. Go to step 20.
No response from attached switch (hello timeout). Go to step 21.