FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/24 Service Manual (AA-RTDXC-TE, July 2004)

Diagnostics
111Edge Switch 2/24 Service Manual
MAP 0700: Fabric, ISL, and Segmented Port Problem
Determination
This MAP describes isolation of fabric logout, interswitch link (ISL), and E_Port
segmentation problems. Failure indicators include:
An event code recorded at the EWS Event Log or Edge Switch Event Log
(HAFM appliance).
A segmentation reason associated with a Fibre Channel port at the EWS
interface.
A yellow triangle (attention indicator) appears adjacent to a port graphic at the
alert panel of the Hardware View.
A link incident message recorded in the Link Incident Log or Port Properties
dialog box.
1
Was an event code 011, 021, 051, 052, 061, 062, 063, 070, 071, 072, 140, 142, or
150 observed at the EWS Event Log or at the Edge Switch Event Log (HAFM
appliance)?
YES NO
Go to step 3.
2
Table 16 lists event codes, brief explanations of the codes, and associated steps
that describe fault isolation procedures.
Table 14: MAP 700 Event Codes
Event Code Explanation Action
011 Login Server database invalid. Go to step 9.
021 Name Server database invalid. Go to step 9.
051 Management Server database invalid. Go to step 10.
052 Management Server internal error. Go to step 10.
061 Fabric Controller database invalid. Go to step 11.
062 Maximum interswitch hop count exceeded. Go to step 12.
063 Remote switch has too many ISLs. Go to step 13.
070 E_Port is segmented. Go to step 14.