Diagnostics
102 Edge Switch 2/24 Service Manual
■ Click expansion port (E_Port) if the port is cabled to a fabric element
(director or switch) to form an ISL.
4. Click Activate to save the configuration information and close the window.
Did reconfiguring the port type solve the problem?
NO YES
↓ The switch appears operational. Exit MAP.
Contact the next level of support. Exit MAP.
24
One of the following mode-mismatch conditions was detected and an ISL
connection is not allowed:
■ The switch is configured for operation in Open Fabric 1.0 mode and is
connected to a fabric element not configured to Open Fabric 1.0 mode.
■ The switch is configured for operation in Open Fabric 1.0 mode and is
connected to a legacy HP switch at the incorrect Exchange Link Parameter
(ELP) revision level.
■ The switch is configured for operation in Open Fabric 1.0 mode and is
connected to a non-HP switch at the incorrect ELP revision level.
■ The switch is configured for operation in Open Fabric 1.0 mode and is
connected to a non-HP switch.
Reconfigure the switch operating mode:
1. Ensure the switch is set offline. Refer to “Set the Switch Online or Offline” on
page 174.
2. At the Hardware View, click Configure > Operating Parameters > Fabric
Parameters. The Configure Fabric Parameters dialog box displays
(Figure 25).