FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/24 Installation Guide (AA-RTDWC-TE, July 2004)
Installing and Configuring the Edge Switch 2/24
80 Edge Switch 2/24 Installation Guide
Figure 25: Configure Ethernet Events dialog box
3. Click the Enable Ethernet Events check box. A check mark displays in the
check box to indicate Ethernet events are enabled.
4.
Also, the value for R_A_TOV must be greater than the value configured for
E_D_TOV.
a value from 10 through 120 minutes in the Ethernet Timeout
field.
5. Click OK to close the dialog box.
Configure, Enable, and Test Call Home Event Notification
Telephone numbers and other information for the call-home feature are
configured through the Windows dial-up networking application. To learn more
about configuring Call-Home features, refer to the HP StorageWorks Edge Switch
2/24 Service Manual. To configure, enable, and test call home event notification:
1. Minimize the Hardware View and return to the HAFM application.
2. At the HAFM or EWS main window, select the Event Notification and Call
Home options from the Monitor menu. The Call Home Event Notification
Setup dialog box displays (Figure 26).
Figure 26: Call Home Event Notification Setup dialog box
3. Click the Enable Call Home Event Notification check box. A check mark
displays in the check box to indicate call-home event notification is enabled.