FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/24 Installation Guide (AA-RTDWC-TE, July 2004)

Installing and Configuring the Edge Switch 2/24
51Edge Switch 2/24 Installation Guide
Install the Edge Switch on a Desktop
To install and configure the Edge Switch on a desktop:
1. Remove the backing from the four adhesive rubber pads and apply the pads to
the underside of the Edge Switch.
2. Ensure that the pads are aligned with the scribed circles at each corner.
3. Position the Edge Switch on a table or desktop as directed by the customer.
Ensure that:
Grounded AC electrical outlets are available.
Adequate ventilation is present.
Areas with excessive heat, dust, or moisture are avoided.
All planning considerations are met. Refer to the HP StorageWorks
HA-Fabric Manager User Guide.
4. Verify all field-replaceable units (FRUs), including small form factor
pluggable (SFP) optical transceivers and combined cooling fan and power
supply assemblies, are installed as ordered.
5. Connect the U.S. or country-specific (optional) AC power cords to the right
(PS0) and left (PS1) receptacles at the rear of the chassis.
WARNING: An HP-supplied power cord is provided for each Edge Switch
power supply. To prevent electric shock when connecting the Edge Switch to
primary facility power, use only the supplied power cords, and ensure that
the facility power receptacle is the correct type, supplies the required voltage,
and is properly grounded.
6. Connect the remaining ends of the AC power cords to separate facility power
sources that provide single-phase, 90 to 264 volt alternating current (VAC)
current. This provides power redundancy.
When the first power cord is connected, the Edge Switch powers on and
performs power-on self-tests (POSTs). During POSTs:
a. The green power (PWR) LED on the front panel illuminates.
b. The amber system error (ERR) LED on the front panel blinks
momentarily while the Edge Switch is tested.
c. The green LEDs associated with the Ethernet port blink momentarily
while the port is tested.