FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/24 Installation Guide (AA-RTDWC-TE, July 2004)
Technical Specifications
139Edge Switch 2/24 Installation Guide
Operating Mode Must select one of two modes:
McData 1.0 or Open Fabric
1.0. The recommended mode is
Open Fabric 1.0.
Open Fabric 1.0 mode
Operating
Parameters
Preferred Domain ID 1
R_A_TOV 10 seconds (100 tenths)
E_D_TOV 2 seconds (20 tenths)
Switch Priority Default
Switch Speed 2 Gb/sec
Rerouting Delay Enabled
SNMP SNMP Communities āpublicā ā 5 NULL strings
SNMP Write Authorizations Read only per community
Trap Recipient IP Addressees 0 for each
UDP Port 162
SNMP Authorization Trap State disabled
Management
appliance
Active Equal Saved State Disabled
Remote Offline Control State Disabled
Zoning Number of Zone Members 0
Number of Zones 0
Number of Zone Sets 0
Zone Names None
Zone Sets Names None
Zone Members None
Default Zone State Disabled
Active Zone Set State Disabled
Active Zone Set Name NULL string
Table 5: Switch Factory-Default Values for Reset Configuration Option (Continued)
Configuration Description Default