FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/24 Installation Guide (AA-RTDWC-TE, July 2004)
Using the Embedded Web Server
102 Edge Switch 2/24 Installation Guide
Configure Switch and Fabric Parameters
Perform this procedure to configure the following switch and fabric operating
parameters: Buffer-to-Buffer Credit (BB_Credit), Error Detect Time Out Value
(E_D_TOV), and Resource Allocation Time Out Value (R_A_TOV), preferred
domain ID, and switch priority.
Configure Switch Parameters
The switch must be set offline to configure operating parameters. To configure the
parameters:
1. Set the switch offline as follows:
a. Choose Operations >Online State to display the Online State tab.
b. Click Set Offline. The message “Your changes have been
successfully activated” displays.
2. Click Configure at the left side of the panel. The Configure panel opens with
the Ports page displayed.
3. Choose Switch >Parameters to display the Operating Parameters tab
(Figure 41).
Figure 41: Switch page—Parameters tab
4. Set the switch parameters:
a. In Preferred Domain ID, enter a value between 1 and 31 (default is 1).
The domain ID uniquely identifies each switch in a fabric.
All fabric-attached switches must have unique domain IDs. If the value is
not unique, the E_Port connection to the switch segments and the switch
cannot communicate with the fabric.