FW V06.02.00/HAFM SW V08.02.00 HP StorageWorks Edge Switch 2/24 Flexport Upgrade Instructions (AA-RTDHE-TE, September 2004)
Table Of Contents

Flexport Upgrade Instructions
15Edge Switch 2/24 Flexport Upgrade Instructions
Configuring the Feature Key
A feature key is an alphanumeric string consisting of both uppercase and
lowercase characters. The following is an example of a feature key format:
XxXx-XXxX-xxXX-xX
The total number of characters may vary. The key is case sensitive and must be
entered exactly as shown in the previous example, including the dashes.
The following procedure tells you how to configure the feature key using HAFM.
If you are using EWS to configure the feature key, refer to online help in the
EWS. If you are using the CLI to configure the feature key, refer to the HP
StorageWorks CLI Reference Guide for Directors and Edge Switches.
After you have obtained the feature key, access HAFM for the switch to be
configured and perform the steps that follow.
Note: If your firmware is 04.01.02 and later, this procedure can be performed while
the switch is online without causing a disruption. If you have firmware earlier than
04.01.02, you must take the switch offline.
1. At the Hardware View, click Configure at the top of the view and select
Features from the pop-up menu. The Configure Feature Key dialog box
displays (Figure 2).
Figure 2: Configure Feature Key dialog box
2. Click New to add a new feature key. The New Feature Key dialog box
displays (Figure 3).
Figure 3: New Feature Key dialog box
3. In the New Feature Key dialog box, type the switch’s feature key and click
OK. The Enable Feature Key dialog box displays (Figure 4).