FW 08.01.00/HAFM SW 08.06.xx or later HP StorageWorks Edge Switch 2/24 Installation Guide (AA-RTDWE-TE, November 2005)

Table Of Contents
Edge Switch 2/24 installation guide 77
example, this information might be that a logical path has been broken because of a
physical event, such as a fiber optic cable being disconnected from a port. Consult with your
HBA and storage device vendor to determine if enabling Domain RSCNs will cause
problems with your HBA or storage products.
d. Select (enable) or clear (disable) the Suppress RSCN on Zone Set Activations check box.
When the parameter is enabled, attached devices do not receive notification following any
change to the fabric's active zone set.
When the parameter is disabled, attached devices (registered through the fabric format
domain register) do receive notification following any change to the fabric's active zone set.
e. Select (enable) or clear (disable) the Limited Fabric RSCN check box.
When enabled, RSCNs are not transmitted after a product initial program load (IPL).
f. Select (enable) or clear (disable) the Zone Flexpars: Isolate Fabric RSCNs on zone activation
changes check box.
When enabled, zone FlexPars isolate and prevent fabric-format RSCNs from propagating to
devices in zones that are not impacted.
g. Enter a value from 1 through 31 (default is 1) in the Preferred Domain ID box.
The domain ID uniquely identifies each switch in a fabric.
NOTE: All fabric-attached switches must have a unique domain ID. If the value is not
unique, the E_Port connection to the switch segments and the switch cannot communicate
with the fabric.
h. Select By Port Speed or Ignore Port Speed from the ISL FSPF Cost Configuration drop-down
list.
By Port Speed—The fastest fabric path is determined by port (ISL) speed. Cost is inversely
proportional to speed.
Ignore Port Speed—ISL speed is ignored, and the fastest fabric path is determined by the
number of hops. Cost is directly proportional to hop count.
4. Click OK to save the information.
The following message is displayed:
Your changes have been successfully activated
5. Set the Edge Switch online (see Setting the Edge Switch offline and online” on page 71).
To configure fabric parameters:
1. Set the Edge Switch offline (see ”Setting the Edge Switch offline and online on page 71).
2. Select Configure > Switch > Fabric Parameters.
The Fabric Parameters view is displayed (Figure 47).