FW 08.01.00/HAFM SW 08.06.xx or later HP StorageWorks Edge Switch 2/24 Installation Guide (AA-RTDWE-TE, November 2005)

Table Of Contents
Edge Switch 2/24 installation guide 63
Backing up HAFM configuration data
It is important to back up the HAFM configuration data. This data is used to restore the HAFM
appliance operating environment in case of hard drive failure. See the HP StorageWorks HA-Fabric
Manager appliance installation guide for instructions on backing up the HAFM configuration data.
Resetting configuration data
You can use the following procedure to reset all Edge Switch configuration data and non-volatile
settings to factory default values.
1. Notify the customer that the Edge Switch is to be set offline. Ensure that the customer’s system
administrator quiesces Fibre Channel frame traffic through the Edge Switch and sets attached
FC-AL devices offline.
2. At the HAFM appliance, open the HAFM appliance application.
3. Set the Edge Switch offline.
For instructions, see ”Setting the Edge Switch online and offline” on page 41.
4. At the HAFM application’s physical map, right-click the product icon representing the switch for
which a configuration file is to be reset to factory default settings, and then select Element
Manager from the pop-up menu.
The application opens.
5. Select the Reset Configuration option from the Maintenance menu.
The Reset Configuration dialog box is displayed (Figure 37).
Figure 37 Reset Configuration dialog box
6. Click Reset to initiate the reset operation and close the dialog box.
The Edge Switch IP address resets to the default address of 10.1.1.10.
If the configured IP address (prior to reset) was the same as the default address, the
switch-to-management appliance Ethernet link is not affected and the procedure is complete.
If the configured IP address (prior to reset) was not the same as the default address, the
switch-to-management appliance Ethernet link drops and server communication is lost.
Continue to the next step.
7. To change the switch IP address and restart the management appliance session, go to step 9.
8. To restart a management appliance session using the default IP address of 10.1.1.10:
a. Close the Element Manager application and return to the HAFM application.
A grey square with a yellow exclamation mark is displayed adjacent to the icon representing
the reset switch, indicating switch is not communicating with the HAFM appliance.
b. At the HAFM application, select Discover > Setup.