FW 08.01.00/HAFM SW 08.06.xx or later HP StorageWorks Edge Switch 2/24 Installation Guide (AA-RTDWE-TE, November 2005)
Table Of Contents
- Edge Switch 2/24 installation guide
- Contents
- Introduction to the Edge Switch 2/24
- Installing the Edge Switch
- Connecting the Edge Switch
- Edge Switch network addresses
- LAN-connecting the Edge Switch
- Setting up the HAFM appliance
- Using HAFM to configure the Edge Switch
- Setting the Edge Switch online and offline
- Configuring Edge Switch identification
- Configuring Edge Switch operating parameters
- Configuring fabric operating parameters
- Configuring switch binding
- Configuring preferred path
- Configuring ports
- Configuring SNMP trap message recipients
- Configuring, enabling, and testing e-mail notification
- Configuring and enabling call-home features
- Configuring and enabling Ethernet events
- Configuring, enabling, and testing call-home event notification
- Threshold alerts
- Creating new alerts
- Figure 30 Configure Threshold Alerts dialog box
- Figure 31 New Threshold Alerts dialog box-first screen
- Figure 32 New Threshold Alerts dialog box-second screen
- Figure 33 New Threshold Alerts dialog box-third screen
- Figure 34 New Threshold Alerts dialog box-summary screen
- Figure 35 Configure Threshold Alerts dialog box-alert activated
- Modifying alerts
- Activating or deactivating alerts
- Deleting alerts
- Creating new alerts
- Configuring SANtegrity Authentication
- Backing up HAFM configuration data
- Resetting configuration data
- Enabling the HAFM Basic interface
- Enabling Telnet
- Connecting the Edge Switch to a fabric
- Using the HAFM Basic interface
- Launching the HAFM Basic interface
- Setting the Edge Switch offline and online
- Configuring Edge Switch ports
- Configuring BB credit
- Configuring Edge Switch identification
- Configuring date and time
- Configuring Edge Switch parameters
- Configuring network information
- Configuring SNMP trap message recipients
- Enabling or disabling the CLI
- Configuring zoning
- Managing firmware versions
- Regulatory compliance and safety
- Technical specifications
- Index

Edge Switch 2/24 installation guide 57
You can use the Threshold Alerts option on the Configure menu to configure the following:
• Name for the alert
• Enter of threshold for the alert (Rx, Tx, or either)
• Active or inactive state of the alert
• Threshold criteria:
• Percent traffic capacity utilized—The percent of the port’s throughput capacity achieved by
the measured throughput. This setting constitutes the threshold value. For example a value of
50 means that the port’s threshold is reached when throughput is 50% of capacity.
• Time interval during which throughput is measured and alert notification can occur.
• The maximum cumulative time that the throughput percentage threshold can be exceeded
during the set time interval before an alert is generated.
• Ports for which you are configuring threshold alerts
You can configure up to 16 alerts, and any number of alerts can be active at one time. Use the
following procedures to create a new threshold alert, or to modify, activate, deactivate, or delete an
alert.
Creating new alerts
1. At the Hardware view, select Configure > Threshold Alerts. The Configure Threshold Alerts
dialog box is displayed (Figure 30).
NOTE: If alerts are configured, they appear in table format showing the name of the alert,
type of alert (Rx, Tx, or Rx or Tx), and alert state (inactive or active).
Figure 30 Configure Threshold Alerts dialog box
2. Click New.