FW 08.01.00/HAFM SW 08.06.xx or later HP StorageWorks Edge Switch 2/24 Installation Guide (AA-RTDWE-TE, November 2005)
Table Of Contents
- Edge Switch 2/24 installation guide
- Contents
- Introduction to the Edge Switch 2/24
- Installing the Edge Switch
- Connecting the Edge Switch
- Edge Switch network addresses
- LAN-connecting the Edge Switch
- Setting up the HAFM appliance
- Using HAFM to configure the Edge Switch
- Setting the Edge Switch online and offline
- Configuring Edge Switch identification
- Configuring Edge Switch operating parameters
- Configuring fabric operating parameters
- Configuring switch binding
- Configuring preferred path
- Configuring ports
- Configuring SNMP trap message recipients
- Configuring, enabling, and testing e-mail notification
- Configuring and enabling call-home features
- Configuring and enabling Ethernet events
- Configuring, enabling, and testing call-home event notification
- Threshold alerts
- Creating new alerts
- Figure 30 Configure Threshold Alerts dialog box
- Figure 31 New Threshold Alerts dialog box-first screen
- Figure 32 New Threshold Alerts dialog box-second screen
- Figure 33 New Threshold Alerts dialog box-third screen
- Figure 34 New Threshold Alerts dialog box-summary screen
- Figure 35 Configure Threshold Alerts dialog box-alert activated
- Modifying alerts
- Activating or deactivating alerts
- Deleting alerts
- Creating new alerts
- Configuring SANtegrity Authentication
- Backing up HAFM configuration data
- Resetting configuration data
- Enabling the HAFM Basic interface
- Enabling Telnet
- Connecting the Edge Switch to a fabric
- Using the HAFM Basic interface
- Launching the HAFM Basic interface
- Setting the Edge Switch offline and online
- Configuring Edge Switch ports
- Configuring BB credit
- Configuring Edge Switch identification
- Configuring date and time
- Configuring Edge Switch parameters
- Configuring network information
- Configuring SNMP trap message recipients
- Enabling or disabling the CLI
- Configuring zoning
- Managing firmware versions
- Regulatory compliance and safety
- Technical specifications
- Index

Connecting the Edge Switch34
The password is case sensitive. The HyperTerminal window is displayed with a C> prompt at
the top of the window (Figure 11).
Figure 11 HyperTerminal window
9. At the C> prompt, enter ipconfig and press Enter.
The HyperTerminal window is displayed with configuration information listed as follows:
• MAC Address
• IP Address (default is 10.1.1.10, factory preset is 10.1.1.10)
• Subnet Mask (default is 255.0.0.0).
• Gateway Address (default is 0.0.0.0)
Only the IP Address, Subnet Mask, and Gateway Address are configurable.
10.Change the IP address, subnet mask, and gateway address as directed by the network
administrator. To change Edge Switch network addresses, enter the following at the C> prompt:
ipconfig xxx.xxx.xxx.xxx yyy.yyy.yyy.yyy zzz.zzz.zzz.zzz
The IP address is always xxx.xxx.xxx.xxx, the subnet mask is always
yyy.yyy.yyy.yyy, and the gateway address is always zzz.zzz.zzz.zzz. The octets xxx,
yyy, and zzz are decimals from zero through 255. If a network address is to remain
unchanged, type the current address in the respective field.
When the new network addresses are configured at the Edge Switch, the message Request
completed OK is displayed at the bottom of the HyperTerminal window.
11.Select File > Exit to close the HyperTerminal application.
A message box is displayed (Figure 12).
Figure 12 Disconnect Now dialog box