FW 08.01.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-330, November 2005)
1
1-8
McDATA Sphereon 4500 Fabric Switch Installation and Service Manual
General Information
Altitude:
40,000 feet (12,192 meters)
Operating
Environment
Temperature:
40
0
F to 104
0
F (4
0
C to 40
0
C)
Relative humidity:
8% to 80%
Maximum wet-bulb temperature:
81
0
F (27
0
C)
Altitude:
10,000 feet (3,048 meters)
Maintenance Approach
The maintenance approach instructs service personnel to perform
fault isolation and repair procedures without degrading or
interrupting product operation or associated applications. Fault
isolation begins when one or more of the following occur:
• Event information displays at a browser-capable PC
communicating with the product through the EFCM Basic
Edition interface.
• Event information displays at a LAN-connected PC or
workstation communicating with the rack-mount management
server running a SAN management application.
• LEDs on the product front panel or FRUs illuminate to indicate a
hardware malfunction.
• An unsolicited SNMP trap message is received at a management
workstation, indicating an operational state change or failure.
• Event notification is received at a designated support center
through an e-mail message or the call-home feature.
Fault isolation and repair information is provided through
maintenance analysis procedures (MAPs). MAPs are step-by-step
procedures that provide information to interpret events, isolate a
failure to a FRU, remove and replace the FRU, and verify product
operation. Fault isolation begins with MAP 0000: Start MAP.