FW 08.01.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-330, November 2005)

A-24
McDATA Sphereon 4500 Fabric Switch Installation and Service Manual
Event Code Tables
Fan Events (300 through 399)
Event Code: 300
Message: Cooling fan propeller failed.
Severity: Major.
Explanation: One cooling fan failed or is rotating at insufficient angular velocity.
Action: Replace the power supply containing the indicated fan module.
Event Data: The first byte of event data (byte 0) specifies the failed fan number.
Distribution: Product Management Server Host
EFCM Basic
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
Log
✔✔✔✔✔✔
Event Code: 301
Message: Cooling fan propeller failed.
Severity: Major.
Explanation: Two cooling fans failed or are rotating at insufficient angular velocity.
Action: Replace the power supply containing the indicated fan module.
Event Data: The first byte of event data (byte 0) specifies the failed fan number(s).
Distribution: Product Management Server Host
EFCM Basic
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
Log
✔✔✔✔✔✔